Supply, Installation, Testing & Commissioning of the following
Electrical works:Supply, Installation,
Testing & Commissioning of the following Electrical works:
HV works including HV cubicle panel & 11kV cable up to tie-in connection point within boundary limit.
Power transformer including bus bar connections.
Generator including ATS
Electrical LV distribution including LV-panel, sub main boards & motor control panel.
Main & sub main cables & cable containment.
Lighting control system.
CCTV system.
Cable containment for building management system.
Lighting installation including lighting points & light switches.
InstallationofFHC’s
Installation only of lights fixtures.
Small power installation including wiring accessories & power isolator.
Earthing & lightning protection system.
Central battery system.
Passive components for Telephone/ Data system.
Access control system
BGM System.
Supply, Installation, Testing & Commissioning of the following MEP works:
Generator including ATS.
Electrical LV distribution including LV-panel, sub main boards & motor control panel
Lighting installation including lighting points & light switches.
Small power installation including wiring accessories & power isolator.
Installation of kWh meter.
Passive components for Telephone/Data system.
Fire Alarm System.
Dry riser system including fireman’s connection & landing valve per floor.
Fire extinguishers & fire blanket.
Automatic gas suppression system. (FM200)
Water Supply and Drainage works
Plumbing equipment including standalone water heaters, water pumps & water tank.
Installation of sanitary wares.
Installation of water meter.
Provision of AC drain, pipe sleeves & copper pipe for DX split AC units.
Ventilation fans.
Air ducts including supports, insulation, fittings, accessories & air outlets.
Supply, Installation, Testing & Commissioning of the following MEP works:
Water supply & drainage piping works.
Plumbing equipment including water pumps, submersible pump, domestic water filter & central water heater.
Conducting visual and preliminary inspection for all field initiating devices (smoke / heat detectors / manual call points/Interface units) and auxiliary field devices (alarm bell / horn strobes) including fire alarm control panel.
Portable fire extinguishers & fire blanket.
VRF air conditioning system with concealed type indoor units.
DX type fresh air handling units.
DX split AC units.
Supply & return air ducts including fittings, accessories & air terminals.
Ventilation fans.
Main sub board & distribution boards
Main & sub main cables including cable containment.
Lighting installation including lighting points & light switches
Installation of light fixtures.
Small power installation including wiring accessories & power isolator.
Standalone fire alarm devices.
Block wiring for telecom system.
Supply, Installation, Testing & Commissioning of the following MEP works:
Generator including ATS.
Electrical LV distribution including LV-panel, sub main boards & motor control panel.
Lighting installation including lighting points & light switches points
Installation only of lights fixtures.
Small power installation including power isolator & power points
Installation of wiring accessories.
Installation of kWh meter..
Passive components for Telephone/Data system.
Fire Alarm System.
Fire pump set & connection to concrete water tank.
Sprinkler & fire hose reel system.
Fire extinguishers & fire blanket.
Automatic gas suppression system (FM200) if required by authority (QCDD).
Water Supply and Drainage works
Plumbing equipments including standalone water heaters, water pumps & water tank.
Installation sanitary wares & accessories.
Installation of water meter.
Gas System.
Chilled water piping works including valve fitting, insulation, supports & accessories.
Chilled water FCU & FAHU.
Heat exchanger unit including chilled water pumps.
Dx split wall mounted AC units.
Ventilation fans.
Air ducts including supports, insulation, fittings, accessories & air outlets.
Fire sealant related to MEP services.
Supply, Installation, Testing & Commissioning of the following MEP works:
LV-Panel
Generator, LV Panel, Main sub board, distribution boards & sub main cables.
Lighting installation including lighting points, light switches & light fixtures.
Small power installation including wiring accessories & power isolator
Cable containment including cable tray, cable trunk & PVC cable ducts.
Lighting Control System
Block wiring for Telecom System
Block wiring for MATV System
Fire Alarm System
Public Address System
IP CCTV system.
Lightning Protection and Earthing System
Fire pump set & connection to concrete water tank.
Sprinkler & fire hose reel system.
Fire Fighting Appliances.
Automatic gas suppression system.
Water Supply and Drainage works
Plumbing equipments including standalone water heaters, water pumps & water tank.
Sanitary wares & accessories.
Chilled Water System
Air ducts including supports, insulation, fittings, accessories & air outlets.
Smoke fans, pressurization fans, exhaust fans & air curtains.
FAHU, FCU’s and DX Split Unit
Water Treatment & Chemical Cleaning System
Building Management System – (provisional sum)
Supply, Installation, Testing & Commissioning of the following MEP works:
LV-Panel, Submain board, distribution boards & sub main cables.
Lighting installation including lighting points, light switches & light fixtures.
Small power installation including wiring accessories & power isolator
Earthing & lightning protection system.
Public Address System
Telecom & Data System/p>
MATV System
Fire Alarm System
Central clocking system
Portable fire extinguishers.
Hose reel & sprinkler system
Water Supply and Drainage works
Plumbing equipments including standalone water heaters, water pumps & water tank.
Sanitary wares & accessories.
Chilled Water System
Supply & return air ducts including supports, fittings, accessories & air outlets. Exhaust fans.
Supply, Installation, Testing & Commissioning of Electrical works including:
Installation of transformer, free standing feeder pillar, LV switchgears, distribution panels, emergency distribution panels & lighting panels.
Installation, testing & commissioning of light fixtures including cabling works, light switches & final termination to distribution boards.
Small power works including wiring accessories.
Earth rods – copper bonded for earthing & lightning.
Installation of UPS panels
LV cable works including cable ladders & termination to substation panel.
Installation & testing of 11KV switchgear
Installation of battery charger
Supply & installation of marshalling box
Supply & installation of substation earthing – solid copper
Supply & installation of 3Cx70mm2 from SS to TX room
Supply & installation of cable termination for 11KV switchgear to the transformer
Supply & installation of LV 1Cx630mm2 LSF cables
Co-ordinate with Kahramaa for getting self-work approval, approval of materials, arrange fitting inspection, test report submission to KM and energizing
Supply, Delivery, Installation, Testing & Commissioning
and handover to Client of the following MEP works in accordance
with the provided drawings and specifications and approved shop drawings.
Electrical works including transformer, LV panel, sub main boards, distribution boards, light fixtures, FA system, CCTV system, block wiring for telecom system and wiring accessories.
Mechanical works including water supply network, drainage piping network, sanitary wares, water supply pumps, standalone water heaters, rotomould water tanks, fire pump, fire hose reel, sprinkler system, AC units and air outlets.
Coordination works with authorities to complete and handover connections works for all MEP services.
All external cables to be direct buried no electrical manholes. Only duct banks consider for road crossing.
All external cables to be direct buried no electrical manholes. Only duct banks consider for road crossing.
Adjustment of quantities in the BOQ as per the provided IFT drawings.
White plastic finish for wiring accessories.
1000 kV A transformer
White plastic finish for wiring accessories.
Wall mounted split AC for offices & 4nos. floor mounted split AC for showroom.
Omission of VRF AC power supply & replace with split AC unit power supply.
Standalone emergency & exit lights